top of page
Enkel Boks RJ45

Enkel Boks RJ45

kr1,500.00Price

Price stated excl. VAT. Linjator box not included.


ENKEL BOKS RJ45 is a full-featured interface system that combines high functionality with simplified cabling. With one UTP cable (TIA/EIA-568B) from the access controller to the box and a separate power cable, the solution provides a more efficient and cost-saving installation without compromising performance. Using decentralized power also removes limitations related to cable spacing, which provides greater freedom and flexibility in the installation. Power can be looped (loop-through) from door to door for further reduction in materials and time. The solution has been developed with regard to requirements in TEK17 for doors and escape routes (including §11-13, §11-14 and §12-13), including fire override and correct configuration of locks in escape routes.

 Main features and benefits

  •  All signals from the access controller are routed in RJ45 wiring (T568B) and are used as control signals for built-in relays in the SINGLE BOX RJ45. This includes, among other things:
    •  Fire alarm control relay
    •  Night lock relay (NC)
    •  Main lock control relay — a specialized relay with a capacity of 8 A is used here, ensuring reliable operation of locks. This relay is designed for a long service life, with an expected operation of up to 25 years.

  •  Separate relay dedicated to the Elbow Switch input signal, which enables simultaneous use of the Elbow Switch both as a REX control signal for access control and as a signal for automatic door opening (AUTO).
  •  Independent voltage levels for control and lock (e.g. 12 V control / 24 V lock – or vice versa) via universal relay coil 10–35 V and separate lock voltage.
  •  Reader support: OSDP (RS-485) and Wiegand can be connected directly via the box for stable and flexible connectivity.
  •  Decentralized power supply with separate cable up to 2×1.5 mm², which can be looped from door to door for easier installation and lower costs.
  •  Simplified cable management and standardized termination (TIA/EIA-568B) provide faster commissioning and fewer misconnections.
  •  Test and status indicators on the circuit board for quick verification during installation, as well as tamper input for secure operation.
  •  Robust dimensioning: up to 5 A on the circuit board's copper tracks (depending on load and terminal type) for reliable operation of door locks and actuators.

 Note: RJ45 is used here as a multi-wire interface (not Ethernet).

  • Compatible with: Ruler 120140 / 120103
  • Dimensions: 104 × 90 × 21 mm
  • Signal cable: UTP Cat 6, TIA/EIA-568B (type B) from ADK controller to SINGLE BOX RJ45
  • Power cable: up to 2×1.5 mm² (separate from UTP), can be looped through
  • Operating voltage: 10–35 V DC, quiescent current ≈ 70 mA
  • Maximum rated current on the PCB copper tracks: up to 5 A
  • I/O: 32 pluggable screw terminals + RJ45 PCB connector (female)
  • Independent levels for control and lock (e.g. 12 V control / 24 V lock) via relays with universal coil 10–35 V
  • FIRE input (dry contact/24 V) with application priority overnight/standard
  • DIP jumpers for local configuration

Signals from ADK

  • Control signal from ADK: 10–35 V
  • Reader interface: OSDP (RS-485) and Wiegand
  • Fire input (control)
  • KAC (manual fire alarm / emergency opening switch, NS-EN 54-11) and sabotage
  • Door status (magnet/microswitch)
  • Main lock control NO/NC 12–24 V
    The choice of operating type (fail-safe / fail-secure) is set with a DIP switch. On doors in escape routes, the lock should be configured as fail-safe.
  • REX / Elbow switch (out/in)

Executive door components

  • Holding magnet (electromagnet) to hold door open – power supply
  • Night lock - power supply/control
  • Automatic door opener (AUTO) – control
  • Elbow switch internal/external – power supply/control (mounted 0.8–1.2 m above the floor and outside the door leaf's swing area)
  • REX button – signal (mounted outside the door leaf swing area)
  • KAC (emergency opening) – signal/control
  • Door magnetic contact / microswitch – signal
  • Main lock NO/NC 12–24 V – power supply/control

Power supply

Constant (always active):

  • Night lock 12–24 V (not on escape doors; there the night lock is fire-controlled and is disconnected in the event of a FIRE)
  • Backlight 12–24 V for readers, KAC and Elbow switch (max 300 mA total)

Fire-controlled (overrides all modes):

  • Holding magnet is disconnected in case of FIRE
  • Night lock 12–24 V deactivated/disconnected in escape route (can be connected via +V HOLD MAGNET)
  • Main lock 12–24 V disconnected for fail-safe opening in escape route
  • FIRE overrides lock in escape route: power is disconnected for fail-safe opening; night override

Contact us